Tea tree trimming pruning time can be carried out from October of the first year to February of the following year. The method is to cut off the irregular branches and leaves of the top of the tea tree so that the flat surface of the tea tree can be formed into a horizontal or curved shape. Generally, the length of the pruning branch is 5-15 cm; Some chicken claws, branches, branches and branches must be deeply pruned; tea gardens with many chicken claws, tea tree aging, tea buds that are not uniform, and have low yield and poor efficiency should be cut and cut off to remove old branches. The height of the pile is about 20 centimeters, so it is conducive to regenerating sprouts and new shoots.

Shizuka Fertilizer To ensure the good quality of tea buds, a complete farm organic fertilizer containing nitrogen, phosphorus and potassium should be used. 200 kg of livestock and poultry excrement should be prepared per mu, 50 kg of dried oil should be added, and 50 kg of calcium-US phosphate fertilizer should be mixed and fermented. Before the fertilization, cultivating the tea plantation once again, digging the soil to a depth of 10-20 cm, preferably not injuring the tea root, and then applying a ditch along the dripping line of the tea awning to deepen the furrow, and then cover the soil.

Diseases and Insect Pest Prevention Tea tree disease, tea coal disease, sheath blight and other diseased trees have been extirpated and burned off in time. The old leaves and branches of the tea tree have been scrutinized once and found. There are eggs, insects, and insects. The branches and branches of the clams are removed in time and the burns are concentrated.

Patient Monitor

Features
10.1 inch high resolution color TFT display
Lightweight and portable design suitable for Ambulance,Emergency Transport
Three Working Modes : Monitoring , Surgery and Diagnosis.
Simple and friendly operating display interface.
Multi-display modes suitable for different applications: Standard Interface , Large font , ECG Standard Full Display ,OXY, Trend able BP Trend.
Built-in high capacity battery up to 3 hours of continuous work


Technique Specification
ECG

Lead Mode : 5 Leads ( I , ll , Ill , AVR , AVL , AVF , V )
Gain : 2.5mm / mV, 5.0mm /mV , 10mm /Mv, 20mm /mV
Heart Rate : 15-300 BPM ( Adult ) ; 15-350 BPM ( Neonatal )
Resolution : 1 BPM
Accuracy : ± 1%
Sensitivity > 200 uV ( Peak to peak )
ST measurement range : -2.0 ~+ 2.0 Mv
Accuracy : -0. 8mV~+ 0. 8mV : ± 0. 02mV or ± 10% , which is greater
Other Range : unspecified
Sweep speed : 12.5 mm / s , 25mm / s , 50mm / s
Bandwidth:
Diagnostic : 0.05~130 Hz
Monitor : 0.5~40 Hz
Surgery : 1~20 Hz

SPO2
Measuring Range : 0 ~ 100%
Resolution : 1%
Accuracy : 70%~100% ( ± 2 % )
Pulse Rate : 20-250 BPM
Resolution : 1 BPM
Accuracy : ± 3 BPM

Optinal Parameters :
Central monitoring system
Dual IBP
Etco 2
12-lead ECG
Nellcor SpO2
Sun Tech NIBP

NIBP
Method : Oscillometry
Measure mode Manual, Auto, STAT
Unit : mmHg , kPa
Measure and alarm range:
Adult Mode
SYS 40 ~ 280 mmHg
DIA 10 ~ 225 mmHg
MEAN 20 ~ 240 mmHg

Pediatric Mode
SYS 40 ~ 220 mmHg
DIA 10 ~ 160 mmHg
MEAN 20 ~ 170 mmHg

Neonatal Mode
SYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHg
Resolution : 1 mmHg
Accuracy : ± 5 mmHg

TEMP
Measure and Alarm Range : 0 ~ 50 C
Resolution : 0 . 1C
Accuracy : ± 0 . 1C

Standard Parameters
ECG, RESP, TEMP, NIBP, SPO2, PR

RESP
Method : Impedance between RA-LL or RALA
Measurement Range:
Adult : 10~120 BrPM
Neonatal / Pediatric : 7~150 BrPM
Resolution : 1 BrPM
Accuracy : ± 2 BrPM

Standard Configuration
No Item Qty

  1. 1 Main Unit 1
  2. 2 5-lead ECG cable 1
  3. 3 Disposable ECG Electrode 5
  4. 4 Adult Spo2 probe 1
  5. 5 Adult NIBP cuff 1
  6. 6 NIBP extension tube 1
  7. 7 Temperature probe 1
  8. 8 Power Cable 1
  9. 9 User Manual 1
  10. 10 Fuse 3

Patient Monitor,Portable Patlent Monltor,Patlent Monltor For Adult,Patlent Monltor For Baby