Points to note when using a single-sided, ultra-clean bench

Points to note when using a single-sided, ultra-clean bench

Double single-sided ultra-clean workbench is widely used in medical and health, bio-pharmaceutical, food, medical science experiments, optics, electronics, laboratory testing, sterile microbial testing, plant tissue culture, etc. And the production department. It is a one-way flow type air purification equipment that provides a local dust-free and sterile working environment. It can also be connected into an assembly line with the advantages of low noise, mobility and the like. It is a kind of air purification equipment with strong versatility for providing local high cleanliness working environment. Its use has good effects on improving process conditions, improving product quality and increasing yield. This article focuses on the points to be aware of when using a single-sided, ultra-clean bench.
The ultra-clean power supply adopts three-phase four-wire power, one of which has a zero line, which is connected to the machine casing, and should be connected to the ground line. The other three lines are phase lines, and the working voltage is 380V. There is a certain order in the three-wire access circuit. If the wire is connected incorrectly, the wind is reversed. At this time, the sound is normal or slightly abnormal. The front of the clean bench is windless (can be observed with alcohol lamp flame, it should not be tested for a long time). Turn off the power in time, and only connect the wire ends of any two of them to the position and connect them. If the three-phase line is only connected to two phases, or one of the three phases is in poor contact, the machine sound is abnormal. You should immediately cut off the power supply and carefully repair it, otherwise the motor will be burnt. These common senses should be explained to the staff when they start using the ultra-clean platform. The exemption should not cause accidents and losses.
The air inlet of the ultra-clean platform is below the back or the front side. There is a common foam sheet or non-woven fabric in the metal mesh cover to block large particles of dust. It should be inspected and removed frequently. If the foam is aging, replace it in time. In addition to the air inlet, if there is a leaking pore, it should be tightly sealed, such as tape, cotton, glued paper, etc. The metal mesh cover on the front of the workbench is a super filter. The super filter can also be replaced. If it is used for a long time, the dust particles are blocked, the wind speed is reduced, and when the aseptic operation cannot be guaranteed, it can be replaced with a new one.
On the clean bench can hoisting ultraviolet lamp, it is to be provided outside the lamp covers, lighting and staggered, so that the work does not interfere with illumination. If the UV lamp is placed inside the lighting cover (glass plate), it is useless. The ultraviolet light cannot penetrate the glass. Its lamp is quartz glass instead of silicate glass.
The vaccination room is intended to be simple, and items that are not directly related to the work of the room cannot be placed in order to maintain sterility. The air in the inoculation room should be absolutely isolated from the outside air, and the reserved ventilation holes should be sealed as much as possible. The venting channel can be provided with upper and lower louvers, and the area of ​​the louver should be slightly larger. It is necessary to cover 4 layers of gauze for simple dust filtering. After a day's work, you can open the window to fully ventilate and then close it. In short, it is clean, dust-free and sterile, and the air is fresh and suitable for work. The gauze covering the ventilation window should be changed frequently. However, the above various measures are only ideal design schemes, and it is often difficult to fully implement them. In fact, only strict aseptic operation procedures are used. In the open windows and doors, there is a clean bench protection, and the pollution rate of inoculation is still controllable in production. level.
The long life of the double-sided ultra-clean workbench and the cleanliness of the air are available. In the temperate zone, the clean bench can be used in general laboratories. However, in tropical or subtropical regions, in areas with atmospheric pollen or dust, the clean bench should be placed in a good indoor room with double doors. . Under no circumstances should the inlet hood of the clean bench be facing the open door or window to avoid affecting the service life of the filter.
The sterile room should be periodically sprayed with 70% alcohol or 0.5% phenol to reduce dust and disinfection, wipe the table top and utensils with 2% Xinjieer (70% alcohol is also available), with UV sterilization lamp (open for more than 15 minutes each time), etc. Sterilization means to keep the sterile room aseptic as usual. The inside of the inoculation box should also be equipped with an ultraviolet lamp. It should be sterilized by turning on the lamp for more than 15 minutes before use. However, it is still bacteriay where it is not exposed. When the UV lamp is turned on for a long time, the oxygen molecules in the air can be excited to form ozone molecules. This gas has a strong bactericidal effect and can sterilize the corners where the ultraviolet rays are not directly irradiated. Since ozone is harmful to health, you should remove the UV lamp before entering the operation, and you can enter it after more than ten minutes.

Natural Plant Extract

Natural Plant Extract is a kind of solid powder obtained by cleaning, extracting, concentrating and spray drying Chinese herbal fruits and vegetables, without adding any other ingredients; The effective components and essence of plants are extracted, which improves the full utilization rate of plants and is beneficial to human absorption.

The components of plant extracts can be divided into glycosides, acids, polyphenols, polysaccharides, terpenoids, flavonoids, alkaloids and so on. For example, the main component of green tea extract is tea polyphenols. Ginseng extract mainly contains a variety of ginseng monomer saponins; According to different characters, it can be divided into extract, powder, lens, etc., such as violet leaf extract, hang white chrysanthemum extract.

Natural Plant Extract,Paeony Extract,Licorice Root Extract,Dong Quai Root Extract

Fufeng Sinuote Biotechnology Co.,Ltd. , https://www.sntextract.com