Five parameters:ECG,NIBP,SPO2,PR,TEMP.
Waveform:ECG and SPO2 waveforms.
Â
Features:
Â
Prior:
Â
Â
Â
Specification:
1. General Specifications:
Size: 209mm×104mm×47.5mm
Net Weight: 655g
Display Specification
Measurement Display: color TFT- LCD/touch screen
Power Supply Indicator: Dual-color LED (red/green)
Charging indicator: A green LED
Â
2. Power Supply
AC Power Adaptor
Input: 100~240VAC, 50/60Hz, 0.7A
Output: DC 5V, 1.5A
Battery
Li-ion rechargeable battery, 3.7V/7200mAH
Operating Time: 15 hours with full battery capacity.
(Condition: 25ºC, NIBP working period is 15 minutes)
Recharge Time: 10 hours.
Â
3. Environment
Temperature
Working:0ºC~45ºC
Transport and Storage: -25ºC~85ºC
Humidity
Working:30% ~85 %
Transport and Storage: 30% ~95 % (no condensation)
Â
4. Monitoring Parameter
ECG
Input:3- lead ECG cable, standard AAMI cable connector
Lead Selection:I,II,III
Gain Selection:×1,×2,×4,×8
Sweep Speed: 12.5, 25, and 50 mm/s
Frequency Response: None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB)
Calibration Signal: 1mV square wave
Protection: Against electrosurgical interference and defibrillation
Heart Rate
Measuring Range: 20 bpm~300 bpm
Renew Time: 1 time per beat
Accuracy: ±1 bpm
Alarm Mode: Audible and visual alarm
SpO2
SpO2%
Measuring Range:0%~100%
Resolution:1 %
Accuracy:±2 %(90%~99%), ±3 %(70%~89%),unspecified (0%~69%)
Pulse Rate
Measuring and Alarm Range:20~300bpm
Resolution: 1bpm
Accuracy: ±1bpm
NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60 (min)
Measuring Period in STAT Mode: 5 min
Cuff Pressure Range:0 mmHg~300mmHg
Pulse Rate Range:30 bpm~250bpm
Measurement Rage: Adult 30 mmHg~255mmHg, Pediatric 30 mmHg~160mmHg
Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg
Pressure Resolution : 1mmHg
The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those measured by trained medical personnel using cuff and stethoscope. The MEAN value measured using this device is equal to that measured using blood pressure measurement device.
Temperature
Input: Body surface thermal-sensitive resistor temperature sensor
Measuring Range: 0ºC~50ºC
Accuracy: ±0.1ºC
Â
5. Storage and Review
Maximum Data Quantity: 3888 groups
Maximum Trend Time: Continuous 129.6 hours
Â
6. Printer (optional)
Type: Thermal micro-printer
Printer Paper: 58 mm thermal paper,Paper roll diameter≤Φ 33mm
Interface: Bluetooth wireless interface
Recording Types: Real-time printing and review data printing
Power Supply:
Rechargeable battery 1700mAh~2000mAh.7.2V. Â
Charge(discharge) :more than 1000times.
Charge time: 2hours
Work Operation/relative humidity:0~55ºC/10~80%RH
Storage Operation/relative humidity:-20~60ºC/10~90%RH
Â
Standard accessories
Â
Standard Packing List
Color palm patient monitor main unit
1 pc
3-lead ECG cable ( include surface TEMP probe)
1pc
Adult finger SpO2 sensor
1 pc
Adult NIBP cuff
1 pc
NIBP extension tube
1 pc
PC software CD
1 pc
BlueTooth Radio
1pc
USB cable
1 pc
AC power adapter
1 pc
Wall bracket
1set
The operator's manual
1 pc
Selectable Accessory
Pediatric NIBP cuff
Â
Five parameters:ECG,NIBP,SPO2,PR,TEMP.
Waveform:ECG and SPO2 waveforms.
Â
Features:
Â
Prior:
Â
Â
Â
Specification:
1. General Specifications:
Size: 209mm×104mm×47.5mm
Net Weight: 655g
Display Specification
Measurement Display: color TFT- LCD/touch screen
Power Supply Indicator: Dual-color LED (red/green)
Charging indicator: A green LED
Â
2. Power Supply
AC Power Adaptor
Input: 100~240VAC, 50/60Hz, 0.7A
Output: DC 5V, 1.5A
Battery
Li-ion rechargeable battery, 3.7V/7200mAH
Operating Time: 15 hours with full battery capacity.
(Condition: 25ºC, NIBP working period is 15 minutes)
Recharge Time: 10 hours.
Â
3. Environment
Temperature
Working:0ºC~45ºC
Transport and Storage: -25ºC~85ºC
Humidity
Working:30% ~85 %
Transport and Storage: 30% ~95 % (no condensation)
Â
4. Monitoring Parameter
ECG
Input:3- lead ECG cable, standard AAMI cable connector
Lead Selection:I,II,III
Gain Selection:×1,×2,×4,×8
Sweep Speed: 12.5, 25, and 50 mm/s
Frequency Response: None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB)
Calibration Signal: 1mV square wave
Protection: Against electrosurgical interference and defibrillation
Heart Rate
Measuring Range: 20 bpm~300 bpm
Renew Time: 1 time per beat
Accuracy: ±Typhoid Rapid Test
Hot Sale Hm-I Medical Color Handheld Multi-Parameter Monitor>
Model NO.: HM-I
Five Parameters: ECG,NIBP,SpO2,Pr,Temp.
Waveform: ECG and SpO2 Waveforms.
Size: 209mm×104mm×47.5mm
Net Weight: 655g
Renew Time: 1 Time Per Beat
Alarm Mode: Audible and Visual Alarm
Charge Time: 2 Hours
Charge(Discharge): More Than 1000times
Printer (Optional) Type: Thermal Micro-Printer
Maximum Trend Time: Continuous 129.6 Hours
Trademark: healicom
Transport Package: Carton
Specification: CE ISO
Origin: Jiangsu, China
HS Code: 901819300
Model NO.: HM-I
Five Parameters: ECG,NIBP,SpO2,Pr,Temp.
Waveform: ECG and SpO2 Waveforms.
Size: 209mm×104mm×47.5mm
Net Weight: 655g
Renew Time: 1 Time Per Beat
Alarm Mode: Audible and Visual Alarm
Charge Time: 2 Hours
Charge(Discharge): More Than 1000times
Printer (Optional) Type: Thermal Micro-Printer
Maximum Trend Time: Continuous 129.6 Hours
Trademark: healicom
Transport Package: Carton
Specification: CE ISO