System function Sample/Reagent/Stirrer system Reaction system Optical system Calibration/QC Operational system Power/ Dimension System function Sample/Reagent/Stirrer system Reaction system Optical system Calibration/QC Operational system Power/ Dimension Cleaning Product,Sponge Brush,Konjac Sponge Qingdao Rongyan Cosmetic Appliance Co.,Ltd , http://www.cosmeticpuff.com
BS-GE200 Hot Sale Medical Devices Electrolyte Analyzer for Laboratory Machine
Throughput: Up to 225 tests/Hour(not including ISE tests)
Test Method: End point, Fixed time, Kinetic
Test Sequence: Discrete, Random access, STAT can be inserted at anytime. Test sequence can be sorted by samples or items
Spectrometer: enclosed array of spectrometer and photodiodes, maintenance free.
Reaction detect: monitor 81 cuvettes's reaction at the same time
Photometric process: the interval time between two consecutive photometric points are exactly the same.
Pipeline system: pressure auto released pumps and double filters to protect pumps and valves
Gearing: plastic gear leads lower noise and accuracy of positioning of moving partsÂ
Environmental resistance: resistant form dust and water vapor
Sample volume:2μL~30μL,step by 0.1μL
Sample tray: 12 positions for primary tubes and secondary cups on one tray, provide two trays convenient for alternate use.
Reagent volume:20μL~300μL, step by 1μL
Reagent tray: embed refrigerated tray provide 30 reagent bottle positions
Reagent bottle: particular reagent bottle without dead volume
Reagent Cooling: continuous cooling system according to the principle of peltier
Probe: inner and outer walls are highly polished leads carry-over <0.1%, level detection and vertical and horizontal collision protection
Stirrer: paddle stirrer coated with Teflon, stir immediately after the sample was added in.
Water consume: <1.5L/hour
Carry over:Optimized item test sequence and reinforced washing process, lower the carry over and avoid probe being clotted
Cuvette material: UV free plastic
Reaction disc: Discal reaction disc with 81 disposable cuvettes
Reaction volume:150μL~600μL
Heater: solid and sealed heater leads temperature raise rapidly and steady and maintenance free
Temperature: 37ºC±0.1ºC
Light source: 12V 20W, halogen lamp with lifetime more than 2000 hours
Spectrometer: post spectrometer with arrayed and sealed filters, maintenance free
Wavelength: 340nm,405nm,450nm,510nm,546nm,578nm,630nm,670nm
Absorbance range: 0~6
Calibration type: single point linear,two points linear,multi-points linear,Logit-4P,Logit-5P,Spline,Exponential 5P,Polynomial 5P, auto choose the best fittest calibration curve.
QC type: real time QC,daily QC,day to day QC
QC chart: L-J,Cumulative sum check,Twin Plot
QC rule: Customized QC rule in order to adapt different item's requirements
Operational system: VISTA,Windows XP,Windows2000
Memory: auto save and recover the results
Report format: Customized report format
Status Check: real time check the working status of the analyzer
Voltage: AC 85V~264V, 55Hz±8Hz, Auto adapt according to the input voltage
Power Consume: ≤350VA
Dimension: 815 mm×625 mm×1100mm(L×W×H)Net weight: 90Kg
Alice Tao
Mobile phone: +86 157 1171 4566
Tel: 020-22090206
Website: www.bisenmedical.com
BS-GE200 Hot Sale Medical Devices Electrolyte Analyzer for Laboratory Machine
Throughput: Up to 225 tests/Hour(not including ISE tests)
Test Method: End point, Fixed time, Kinetic
Test Sequence: Discrete, Random access, STAT can be inserted at anytime. Test sequence can be sorted by samples or items
Spectrometer: enclosed array of spectrometer and photodiodes, maintenance free.
Reaction detect: monitor 81 cuvettes's reaction at the same time
Photometric process: the interval time between two consecutive photometric points are exactly the same.
Pipeline system: pressure auto released pumps and double filters to protect pumps and valves
Gearing: plastic gear leads lower noise and accuracy of positioning of moving partsÂ
Environmental resistance: resistant form dust and water vapor
Sample volume:2μL~30μL,step by 0.1μL
Sample tray: 12 positions for primary tubes and secondary cups on one tray, provide two trays convenient for alternate use.
Reagent volume:20μL~300μL, step by 1μL
Reagent tray: embed refrigerated tray provide 30 reagent bottle positions
Reagent bottle: particular reagent bottle without dead volume
Reagent Cooling: continuous cooling system according to the principle of peltier
Probe: inner and outer walls are highly polished leads carry-over <0.1%, level detection and vertical and horizontal collision protection
Stirrer: paddle stirrer coated with Teflon, stir immediately after the sample was added in.
Water consume: <1.5L/hour
Carry over:Optimized item test sequence and reinforced washing process, lower the carry over and avoid probe being clotted
Cuvette material: UV free plastic
Reaction disc: Discal reaction disc with 81 disposable cuvettes
Reaction volume:150μL~600μL
Heater: solid and sealed heater leads temperature raise rapidly and steady and maintenance free
Temperature: 37ºC±0.1ºC
Light source: 12V 20W, halogen lamp with lifetime more than 2000 hours
Spectrometer: post spectrometer with arrayed and sealed filters, maintenance free
Wavelength: 340nm,405nm,450nm,510nm,546nm,578nm,630nm,670nm
Absorbance range: 0~6
Calibration type: single point linear,two points linear,multi-points linear,Logit-4P,Logit-5P,Spline,Exponential 5P,Polynomial 5P, auto choose the best fittest calibration curve.
QC type: real time QC,daily QC,day to day QC
QC chart: L-J,Cumulative sum check,Twin Plot
QC rule: Customized QC rule in order to adapt different item's requirements
Operational system: VISTA,Windows XP,Windows2000
Memory: auto save and recover the results
Report format: Customized report format
Status Check: real time check the working status of the analyzer
Voltage: AC 85V~264V, 55Hz±8Hz, Auto adapt according to the input voltage
Power Consume: ≤350VA
Dimension: 815 mm×625 mm×1100mm(L×W×H)Net weight: 90Kg
Alice Tao
Mobile phone: +86 157 1171 4566
Tel: 020-22090206
Website: www.bisenmedical.com
BS-Ge200 Hot Sale Medical Devices Electrolyte Analyzer for Laboratory Machine>
Model NO.: BS-GE200
Absorbance Range: 0~6
Power Consume: ≤350va
Sample Volume: 2μl~30μl,Step by 0.1μl
Product Name: Blood Gas Analyzer
Reaction Volume: 150μl~600μl
Name: Electrolyte Analyzer
Test Method: End Point ,Fixed Time, Kinetic
Certificate: Ce ISO
Trademark: Bisen
Transport Package: Standard Carton Box for Export
Specification: 1
Origin: China, Guangzhou
Model NO.: BS-GE200
Absorbance Range: 0~6
Power Consume: ≤350va
Sample Volume: 2μl~30μl,Step by 0.1μl
Product Name: Blood Gas Analyzer
Reaction Volume: 150μl~600μl
Name: Electrolyte Analyzer
Test Method: End Point ,Fixed Time, Kinetic
Certificate: Ce ISO
Trademark: Bisen
Transport Package: Standard Carton Box for Export
Specification: 1
Origin: China, Guangzhou
Next Article
High Quality Disposable Nitrile Gloves